OD6 blocking for weak fluorescence
In biochemical detection, residual excitation light can mask weak emission signals. OD6 blocking is often specified to reduce detector-side leakage.
Precision Optical Filters — Factory Direct from OPTOStokes
Compare OD6 fluorescence filters for ELISA readers, microplate detection, POCT modules, PCR optical paths, and flow cytometry channels where weak signals must be separated from excitation light.
Start from the assay wavelength or fluorescence channel, then confirm CWL, FWHM, peak transmission, and OD6 blocking range. For weak fluorescence signals, blocking depth and detector-side stray-light control are often as important as peak transmittance.
Microplate readers and ELISA instruments use filtered monochromatic light to measure absorbance or fluorescence in small sample volumes. For fluorescence-based biochemical analysis, POCT modules, PCR optical paths, and flow cytometry channels, OD6 blocking helps suppress excitation leakage before it reaches the detector.
Compare related Narrow Bandpass Filters
| Model | Spectral Range | CWL (nm) | FWHM (nm) | Peak Transmittance | Blocking |
|---|---|---|---|---|---|
| STO-NBP365/10N | UV | 365±2 | 10±2 | T>60% | OD6 @ 200-800nm |
| STO-BP470/30N | Visible | 470±2 | 30±2 | T>70% | OD6 @ 200-800nm |
| STO-BP523/25N | Visible | 523±2 | 25±2 | T>70% | OD6 @ 200-800nm |
| STO-BP525/20N | Visible | 525±2 | 20±2 | T>70% | OD6 @ 200-800nm |
| STO-BP543/20N | Visible | 543±2 | 20±2 | T>70% | OD6 @ 200-800nm |
| STO-BP564/25N | Visible | 564±2 | 25±2 | T>70% | OD6 @ 200-800nm |
| STO-BP571/20N | Visible | 571±2 | 20±2 | T>70% | OD6 @ 200-800nm |
| STO-BP584/20N | Visible | 584±2 | 20±2 | T>70% | OD6 @ 200-800nm |
| STO-BP612/20N | Visible | 612±2 | 20±2 | T>70% | OD6 @ 200-800nm |
| STO-BP615/20N | Visible | 615±3 | 20±3 | T>70% | OD6 @ 200-800nm |
| STO-BP624/40N | Visible | 624±3 | 40±4 | T>70% | OD6 @ 200-800nm |
| STO-BP635/20N | Visible | 635±2 | 20±2 | T>70% | OD6 @ 200-800nm |
| STO-BP635/30N | Visible | 635±2 | 30±2 | T>70% | OD6 @ 200-800nm |
| STO-BP655/20N | Visible | 655±2 | 20±2 | T>70% | OD6 @ 200-800nm |
| STO-BP680/20N | Visible | 680±2 | 20±2 | T>70% | OD6 @ 200-800nm |
| STO-NBP683/15N | Visible | 683±2 | 15±2 | T>70% | OD6 @ 200-800nm |
| STO-BP692/40N | Visible | 692±3 | 40±4 | T>70% | OD6 @ 200-800nm |
| STO-BP716/20N | NIR | 716±2 | 20±2 | T>70% | OD6 @ 200-800nm |
In biochemical detection, residual excitation light can mask weak emission signals. OD6 blocking is often specified to reduce detector-side leakage.
Absorbance and fluorescence assays often use channels around 405nm, 450nm, 492nm, 630nm, and related visible fluorescence bands. Confirm the assay kit and detector response before selecting a filter.
For POCT, PCR, or compact fluorescence modules, share the optical path, light source, detector, AOI, and mechanical size so the filter stack can be reviewed as a system.
Common channels include 405nm, 450nm, 492nm, 630nm, and assay-specific fluorescence bands depending on the detection chemistry.
Narrow passbands improve wavelength discrimination while OD6 blocking helps suppress stray excitation energy before it reaches the detector.
Yes. OPTOStokes can review fluorescence filters and optical module requirements for POCT, PCR, biochemical analysis, and custom detector assemblies.
Quality & Compliance
For OEM programs, laboratory instruments, and industrial systems, OPTOStokes keeps quality, material compliance, and engineering support visible from the start of supplier evaluation.
Process control, inspection records, and repeatable coating workflows for production optical components.
Compliance documentation can be prepared for qualified projects and regulated supply chains.
Wavelength, FWHM, substrate, AOI, size, and mounting requirements can be reviewed with engineering.
Share target wavelength, blocking level, transmittance, and drawing requirements for a focused quote.
Our engineers will help you select the perfect optical solution.