Welcome to OPTOStokes Filters - Precision Optical Solutions!

Cy5 Alternatives & Photobleaching Prevention for Imaging

Visits:
Fluorescence DyeExcitation filter (nm)Emission filter (nm)Dichroic mirror (nm)
Atto 425BP430/24BP480/30DM450
BP430/24BP480/20DM450
FAMBP470/30BP520/20DM505
BP470/30BP525/20DM505
BP480/20BP520/20DM505
BP485/20BP525/20DM505
HEX,VIC,JOEBP520/20BP565/22DM550
BP525/20BP565/22DM550
BP530/20BP565/22DM550
BP530/20BP570/20DM550
CY3,TAMRABP543/20BP580/20DM565
BP543/20BP585/20DM565
ROXBP565/22BP615/40DM590
BP570/20BP612/20DM590
BP580/20BP620/20DM600
BP585/20BP620/20DM600
Atto 633BP620/20BP655/20DM635
CY5BP624/40BP694/40DM647
BP624/40BP675/20DM647
BP630/20BP675/20DM647
BP630/20BP680/20DM647
CY5.5BP675/20BP725/30DM700
BP665/22BP725/40DM700
CY7BP715/70BP800/60DM770
BP725/30BP800/30DM770
BP725/40BP800/30DM770

1. Top Cy5 Alternatives in Fluorescence Imaging

Cy5 is widely used in far-red fluorescence imaging, but researchers often seek alternatives for specific needs. Two leading options stand out:   - Alexa Fluor 647: Matches Cy5’s spectral profile with excitation ~650nm and emission ~668nm, offering superior photostability—ideal for long-term live-cell imaging.   - Allophycocyanin (APC): A phycobiliprotein with excitation ~650nm and emission ~660nm, prized for high brightness in flow cytometry.   Both alternatives share Cy5’s compatibility with red-channel imaging systems, making them drop-in replacements with minimal setup adjustments.

2. OPTOStokes Filters for Cy5 Substitutes

To maximize performance with these alternatives, filter sets must align with their spectral peaks. OPTOStokes provides:   - Stock Filter Sets: Pre-calibrated for Alexa Fluor 647 (excitation 650/20nm, emission 670/20nm) and APC (excitation 650/15nm, emission 660/20nm).   - Custom Solutions: Tailored bandwidths or dichroic mirrors (e.g., DM655nm) for unique imaging systems, ensuring zero crosstalk.   All filters maintain >90% transmission in passbands, reducing exposure time—critical for photostability.

3. How to Prevent Photobleaching in Cy5 & Alternatives

Photobleaching (fluorescence loss from light exposure) undermines data reliability. Key strategies:  

- Minimize Exposure: Use high-transmission filters (like OPTOStokes’ >90% models) to reduce laser power/imaging time.  

- Anti-Fading Agents: Pair with reagents (e.g., DABCO) to slow dye degradation—compatible with all Cy5 substitutes.  

- Filter Quality: Choose filters with tight blocking (OD6+ in off-bands) to avoid stray light accelerating bleaching.   

- Regular Checks: Inspect filter surfaces for degradation; replace with OPTOStokes’ durable coatings (scratch-resistant) when needed.

4. Get Started with OPTOStokes

Need help with Cy5 alternatives or photobleaching?   

 - Email sales@optofilters.com for:   

- Free spectral compatibility checks for your imaging system   

- Custom filter designs for Alexa Fluor 647/APC   

- Visit our site to:   - Browse in-stock Cy5 substitute filter sets 

 - Request a no-obligation quote   OPTOStokes: Precision filters for stable, high-quality fluorescence imaging—when you need them.

Leave Your Message


Leave a message