Product Description
LP7700 Long Wave Pass Filter: 7.7 μ m Cut off, 8000-11000nm High Transmittance, 0.5mm Thick
LP7700 is a long wave pass filter: thermal infrared radiation above 7.7 μ m should be emitted as much as possible, and all radiation below 7.7 μ m should be blocked. It is installed in the front optical path of thermal imaging and human infrared sensing. It is different from a bandpass strip - a bandpass strip cuts off both ends, a long pass strip only cuts off the short wave end, and the amount of energy above 7.7 μ m is sent to the detector. This difference determines that it is suitable for situations where "heat radiation is collected as much as possible" and not suitable for situations where "only a small wavelength is taken".
Technical specifications
| Parameters | Specifications | Description |
|---|---|---|
| Product model | LP7700 | Model nominal cutoff wavelength 7700nm |
| Through the interval | 8000-11000nm, T>; 90% | Long wave side high transmittance segment |
| Cut off interval | 1500-7300nm, OD>; 2 | OD2 corresponds to a transmittance of 1% |
| Transition zone | Approximately 7300-8000nm | Defined by the above two boundary segments, the edge shape is based on the measured curve |
| Base material | Silicon wafer | Band matching is described below |
| Incident angle | 0 ° | Other working angles need to be confirmed separately |
| Thickness | 0.5mm | Single substrate thickness |
| Appearance/Dimensions | Confirm according to inquiry | No fixed specifications specified on this page |
The transition bandwidth is about 700nm, and the relative cutoff wavelength is close to 10%, which is a conventional level in long pass filters - the edge steepness of long pass filters is naturally not as good as that of narrow pass filters, because their film system needs to suppress over a span of over one thousand nanometers. If the system requires steeper edges, it can only rely on increasing the number of membrane layers or stacking a second layer, both of which will increase costs.
The substrate step is more prone to errors than the membrane system
The specifications are for silicon wafers, but there is one thing that must be checked: the transmission window of optical silicon is roughly between 1.2-7 μ m. After exceeding 7 μ m, the absorption of lattice vibrations rapidly increases, and by 8-11 μ m, it is close to opacity. That is to say, a 0.5mm thick silicon wafer cannot achieve 90% transmittance between 8000-11000nm, and these two parameters cannot be held simultaneously.
There are only a limited number of transmissive materials available for long wave infrared energy: germanium (about 2-14 μ m), zinc selenide (about 0.6-21 μ m), zinc sulfide (about 0.4-12 μ m), and barium fluoride (about 0.15-12 μ m). Among them, germanium matches this specification the best: it covers a range of 8-11 μ m with more than enough transparency, and is naturally opaque below 1.8 μ m - which means that the material itself has already taken on most of the blocking around 1500nm, and the membrane system only needs to handle the 2-7.3 μ m range. 0.5mm is also the conventional thickness of germanium flakes.
So whether the actual substrate is silicon, germanium or other materials needs to be verified with the supplier before finalizing. This is not a matter of wording: the material selection is incorrect, and the transmittance of 8-11 μ m is directly reset to zero, not discounted.
Thermal imaging and human body induction: a parameter based selection deduction
The following is a deduction example, not a customer case.
Requirement: Non heating and cooling imaging module or pyroelectric induction module, detector is a micro radiometer or dual element pyroelectric element, which needs to work in a mixed environment of daytime outdoor and nighttime lighting. It is required to block visible light and near-infrared interference, and only retain the thermal radiation of the target.
Why use long pass instead of band-pass: Thermal imaging is an application for "energy harvesting", where detectors require as much thermal radiation as possible in exchange for temperature resolution. The Changtong film passes the entire section above 7.7 μ m without wasting any energy of 8-11 μ m; If we switch to a long wave bandpass, the thermal radiation outside the passband will be cut off, and the noise equivalent temperature difference will deteriorate. Only when it is necessary to distinguish specific bands (such as multispectral temperature measurement), is a versatile band the correct choice.
Why cut at 7.7 μ m: The radiation energy of objects at room temperature is mainly distributed above 8 μ m. The 7.7 μ m position can block the short wave components in solar reflection and illumination, without cutting to the target's radiation body. Cutting shorter will result in signal loss, while cutting longer will not block shortwave interference. 7-8 μ m is a repeatedly verified inflection point.
Regarding the term "infrared night vision": In the Chinese context, it mostly refers to the active infrared night vision of cameras -850nm or 940nm infrared light supplement, silicon CMOS imaging, which belongs to near-infrared and is completely different from LP7700. The LP7700 is designed for long wave infrared thermal imaging and pyroelectric induction, observing the thermal radiation emitted by the object itself without relying on any supplementary light. Separate these two paths when selecting, which can save a lot of ineffective communication.
Applicable boundary: 0 ° collimated optical path; The detector response covers 8-11 μ m; The ambient temperature is relatively stable or shutter calibration has been performed.
Before placing an order, it is necessary to verify the substrate material and its actual transmission at 8-11 μ m; 1500-7300nm full range blocking curve, with a focus on the transition around 7 μ m; Does the upper limit of detector response exceed 11 μ m? If the detector can respond to 14 μ m, the cutoff position on the long wave side needs to be renegotiated.
Two easily trampled misjudgments
One reason is that they thought adding Changtong tablets would enable them to work stably 24/7. Long pass filters only solve short wave interference and cannot block the solar radiation that already exists within 8-11 μ m. During the day outdoors, sunlight still has considerable energy in this wavelength range. When it is reflected by objects and enters the lens, it can cause the background to rise, the image to appear gray, and even result in a "sun blind" failure. This is not a problem with the filter, it needs to rely on shutter correction, temperature drift compensation, or algorithm processing. Treating Changtong tablets as a universal solution will surely disappoint the audience on site.
The second is to apply the existing experience of "infrared night vision" to this band. Near infrared night vision relies on reflected light imaging. By changing the lens and adding a filter, the image can be viewed immediately; Long wave infrared relies on the temperature difference of the target itself. A glass at the same temperature is almost transparent in a thermal imager, while a metal plate at room temperature reflects the surrounding environment like a mirror. The physical foundations of the two types of imaging are different, and the design of the optical path, lens materials, and window selection all need to be redone. Using the intuition of visible light for thermal infrared is the most common reason for rework in such projects.
Customization and delivery support
The cutoff wavelength and transition band width can be adjusted according to the project, the substrate material (germanium, zinc selenide, zinc sulfide, etc.) can be specified, the long wave side anti reflection can be optimized, the transmission range can be expanded or narrowed, the thickness and shape can be changed, and a set of snap rings can be matched. Samples and measured spectral data can be provided by project. Batch applications require a batch tolerance for the cut-off wavelength and a minimum aperture for blocking - the consistency of coating in long wave infrared is more difficult to control than in visible bands, and this should be included in the protocol. The selection ideas for filters belonging to the same category of long wave infrared can refer to<a href=“ https://www.optofilters.com/article/case/LWIR-Filter-Selection-for-NH3-Sensors.html Long wave infrared filter selection case; for more categories, see<a ref=" https://www.optofilters.com/product/OpticalFilters.html Classification of Optical Filter Products
Information required for inquiry
Please provide: cutoff wavelength and transition band requirements, upper and lower boundaries of the transmission range, substrate material requirements, detector model and response range, incident angle and optical path form, external dimensions and aperture, working environment temperature, and annual usage. The first and fourth points are the most crucial - the cutoff position determines what it can block, and the upper limit of the detector response determines where the long wave side should switch. Technical Consultation and Inquiry: sales@optofilters.com , or through<a ref=“ https://www.optofilters.com/single/contact-us.html Contact us on thepage to submit.
Tags: 7.7 μ m long pass filter LWIR long pass filter thermal imaging filter human body sensing filter LP7700